Extract_DLLs_from_GAC

Snippet Name: Extract_DLLs_from_GAC

Tags:

Created Date: 2025-06-16 13:12:46
Last Modified Date: 2025-05-31 10:31:50

Dependencies:

DBA Notes:

Sample Output:

Title: Extract DLLs from GAC
Author: user
i have  a windows server, and i need to extract some specific dlls from te global assembly cache, so they can be registered on another server. i am looking for Renci.SshNet.dll and SshNet.Security.Cryptography.dll

Author: ChatGPT
To extract specific DLLs from the Global Assembly Cache (GAC) on a Windows Server, such as `Renci.SshNet.dll` and `SshNet.Security.Cryptography.dll`, you can follow these steps:

### Method 1: Using Windows Explorer
1. Open **File Explorer** and navigate to the GAC, which is located at:
   - `C:\Windows\Microsoft.NET\assembly\GAC_MSIL\` for .NET assemblies.
2. In this directory, you'll find subfolders corresponding to different assemblies.
3. Look for the folder named `Renci.SshNet` or `SshNet.Security.Cryptography` (or variations thereof).
4. Once found, open the folder. Inside, you should see versioned subdirectories containing the DLLs.
5. Copy the required DLLs to the desired location.

### Method 2: Using PowerShell
Alternatively, you can use PowerShell to locate and copy the DLLs from the GAC:

1. Open PowerShell as an administrator.
2. Run the following script to list the assemblies:
   ```powershell
   [System.Reflection.Assembly]::LoadWithPartialName("Renci.SshNet")
   ```
3. You can retrieve the path of the DLLs using the following command:
   ```powershell
   $dllPath = [System.Reflection.Assembly]::LoadWithPartialName("Renci.SshNet").Location
   Copy-Item -Path $dllPath -Destination "C:\path\to\destination"
   ```

4. Repeat this process for the `SshNet.Security.Cryptography.dll` if it's also in the GAC.

After extracting the DLLs, you can register them on the new server using `regsvr32` if necessary.

Let me know if you need more details for specific steps.

Author: user
can you show me the regsvr32 command to add the dll to the gac?

Author: ChatGPT
`regsvr32` is typically used for registering COM components, not for registering .NET assemblies in the Global Assembly Cache (GAC). To register a .NET assembly (such as `Renci.SshNet.dll`) in the GAC, you need to use the **Global Assembly Cache Tool (`gacutil`)**.

### Steps to Register a DLL in the GAC using `gacutil`:

1. **Install the .NET SDK** (if not already installed) to ensure you have `gacutil.exe`. It is typically found in:
   - `C:\Program Files\Microsoft SDKs\Windows\vX.X\Bin\gacutil.exe`
   
2. Open **Command Prompt** as Administrator.

3. Use the following command to register the DLL in the GAC:
   ```cmd
   gacutil /i "C:\path\to\Renci.SshNet.dll"
   gacutil /i "C:\path\to\SshNet.Security.Cryptography.dll"
   ```

This will add the assemblies to the GAC.

If you don't have `gacutil.exe`, you can use **PowerShell** or the .NET Framework methods to add assemblies to the GAC.

Let me know if you need further clarification or help with the installation of the SDK.


Leave a Reply